Maintenance knowledge
The machine can not start:
1 turn on the power, turn on the power switch and check the fuse.
The
2 release of the emergency stop button.
3 turn on the air pressure, keep about 6 kilograms.
4 check whether the switch power supply DC24V power output.
5 check the touch screen and PLC communication line is loose.
Two: no material:
1 check the air pressure, check the touch screen maintenance mode.
2 material mouth is closed, check circuit.
3 feeding.
4 check the air pressure, check whether the injection cylinder and cylinder is dead, check the touch screen maintenance mode screen mouth is closed, check circuit.
Three: filling dose is not allowed:
1 check feed system.
2 filter and clean the material.
3 replace the pneumatic valve seal, air leakage, replace the pneumatic valve.
4 clean the solenoid valve, replace the solenoid valve.
5 fire blasts and replacing Fire Blast cleaning.
6 adjust the valve to reduce the impact force, increase the depth.
7 replace the O ring.
8 adjust the magnetic switch of injection cylinder.
Four: leakage:
1 a feeding mouth, replacement feeding mouth sealing pad.
2 replace the material pipe.
3 clean the pneumatic valve, replace the pneumatic valve gasket.
4 replace the injection cylinder sealing ring.